PART 1 - GENERAL

1.01 SUMMARY

  1. Section Includes: Sliding/folding aluminum and glass door system, including aluminum frame, threshold, panels, sliding/folding and locking hardware, weather stripping, glass and glazing; designed to provide an opening glass wall, with sizes and configurations as shown on drawings and specified herein, SL72 NanaWall®, Miami Dade County & Florida State Hurricane Approved, Aluminum Framed Folding System by Nana Wall Systems, Inc.

1.02 REFERENCES

  1. Metro-Dade County, FL Building Code Compliance Office Protocol:
    1. TAS 201-94, Impact Test Procedures
    2. TAS 202-94, Criteria for Testing Impact and Non Impact Resistant Building Envelope Components Using Uniform Static Air Pressure
    3. TAS 203-94, Criteria for Testing Products Subject to Cyclic Wind Pressure Loading.
  2. American Architectural Manufacturers Association (AAMA):
    1. AAMA 611.98, Voluntary Specification for Anodized Architectural Aluminum.
    2. AAMA 2603.02, Voluntary Specifications, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels.
    3. AAMA 1303.5, Voluntary Specifications for Forced Entry Resistant Aluminum Sliding Glass Doors.
  3. American Society for Testing and Materials (ASTM):
    1. ASTM E 283, Test Method for Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
    2. ASTM E 330, Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
    3. ASTM E 547, Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential.
  4. American National Standards Institute (ANSI):
    1. ANSI Z97.1, Safety Performance Specifications and Methods of Test for Safety Glazing Material Used In Buildings.
  5. Consumer Product Safety Commission (CPSC):
    1. CPSC 16CFR-1201, Safety Standard for Architectural Glazing Materials.

1.03 SUBMITTALS

  1. Detail Drawings: Indicate dimensioning, direction of swing, configuration, swing panels, typical head jamb, side jambs and sill details, type of glazing material and handle height.
  2. Product Data: Manufacturer's literature including independently tested data listing performance criteria and Owner's Manual with installation instructions.
  3. Contract Closeout Submittal: Submit copy of the entire Miami-Dade County, FL Notice of Approval and Owner's Manual from manufacturer. Identify with project name, location and completion date, type and size of unit installed.

1.04 QUALITY ASSURANCE

  1. Manufacturer: Provide complete, precision built, engineered, pre-fitted unit by a single source manufacturer with at least 15 years experience in providing folding/sliding door systems for large openings in the North American market.
  2. Performance Criteria: Approved in accordance with Miami Dade County Test Protocols TAS 201-94 (large and small missile impact), TAS 202-94 (structural pressure, air infiltration, water infiltration, forced entry), and TAS 203-94 (cyclic pressure). Also Florida statewide approved with Certificate of Product Approval # FL2947 and complies to equivalent ASTM standards.
    SPECIFIER'S NOTE: Miami Dade County, Florida approval is for any number of panels with any panel size up to a maximum of 3'0" wide increments and 8'0" high. Only a unit with a raised sill or low profile saddle sill is approved.
    Inswing system with raised sill and single impact glass achieved negative design pressure rating of 90 psf (with heat strengthened impact glass, lower limits with annealed impact glass). Inswing system with a low profile saddle and/or insulated impact glass achieved negative design pressure rating of 60 psf. All inswing units with a raised or low profile saddle sill achieved positive design pressure rating of 55 psf. The SL72 inswing system is approved with Miami Dade County, Florida Notice of Acceptance No. 02-0927.09 with expiration date of January 9, 2008.

    All outswing system units achieved negative design pressure rating of 55 psf and positive design pressure rating of 55 psf. The SL72 outswing system is approved with Miami Dade County, Florida Notice of Acceptance No. 02-0927.08 with expiration date of January 9, 2008.

    Building departments in other areas outside of Miami Dade County, FL, may, with an engineering letter based on comparative analysis, accept units to meet higher design pressures or units with larger size panels. (Comparative analysis charts published by manufacturer shows which panel sizes (if any) would meet the structural loading design pressures specifically required for the project).
  3. Installer Qualifications: Installer experienced in the installation of manufacturer's products or other similar products for large openings. Installer to provide reference list of at least 3 projects of similar scale and complexity successfully completed in the last 3 years. Provide project names, locations, completion dates, names and telephone numbers of General Contractor's and Owner's contact person.

1.05 WARRANTY

  1. Provide manufacturer's standard warranty against defects in materials and workmanship.
  2. Warranty Period: Ten years for rollers. For all other components, one year (two years if unit is installed by manufacturer's certified trained installer) from date of delivery by manufacturer.

PART 2 — PRODUCTS

2.01 SUPPLIER

  1. NANA WALL SYSTEMS, INC.
    707 Redwood Highway, Mill Valley, CA 94941
    Toll Free: (800) 873-5673
    Telephone: (415) 383-3148
    Fax: (415) 383-0312
    Website: www.nanawall.com
    Email: info@nanawall.com

2.02 MATERIALS

  1. Frame and Panels: From manufacturer's standard profiles, provide head jamb, side jambs, and panels with dimensions shown on drawings.
    1. Provide standard bottom rail [OR manufacturer's standard kickplate with height specified [Not Dade County approved].
    2. Aluminum Extrusion: Extrusions with nominal thickness of .098" (2.5 mm). Alloy specified asAIMgSi0.5 with strength rated as 6063-T5 or F-22 (European standard). Anodized conforming to AAMA 611.98 or powder coated conforming to AAMA 2603.02.
    3. Aluminum Finish: Dark bronze anodized, E6 C34 [OR clear anodized, E6 EV1] [OR white powder coated, RAL 9016] [OR select from range of RAL high gloss powder coated finishes available from manufacturer] [OR select from range of RAL matte powder coated finishes available from manufacturer] [OR custom finish].
  2. Glass: Provide manufacturer's standard annealed [OR heat strengthened] 7/16" thick laminated impact glass glazed in accordance with Dade county approval [OR 1 1/8" thick insulated impact heat strengthened glass].
  3. Locking Hardware and Handles: Provide manufacturer's standard nylon handle and concealed two point locking hardware operated by 180 degree turn of handle between each pair of folding panels and on any secondary swing panel. Face applied flush bolt locking will not be allowed.
    1. For locking operation from inside only, on main entry swing panel or pair of bi-fold panels, provide manufacturer's standard nylon handle and concealed two point locking hardware operated by 180 degree turn of handle. [OR On the main entry panel for models with a swing panel, provide manufacturer's standard nylon lever handles on the inside and outside, a Schlage compatible lock set with lockable latch, dead bolt and rods at the top and bottom. Rods to be concealed and not edge mounted. Depression of handles withdraws latch. Lifting of handles engages rods and turn of key or thumb turn engages deadbolt and operates lock.]

      [OR On the main entry panel for models with a swing panel, provide HEWI 550.33 ADA nylon pull handles with separate lock set and dead bolt. (Not Dade County approved.)]
      SPECIFIER'S NOTE: This option is recommended with a door closer, but note that a door closer is not possible for a swing panel not attached to a side jamb.
      [OR On main entry pair of panels of models without a swing panel, provide manufacturer's standard nylon L-shaped handle on the inside and outside, a lock set with two point locking operated by 180 degree turn of handle.]
    2. Nylon handle finish: closest match to frame and panel finish color from 13 available colors.
    3. Aluminum locking rods capped by with fiber glass reinforced polyamide end caps at top and bottom. Rods to have a stroke of 15/16" (24 mm).
    4. Provide handle height centered at 41 3/8" [OR as specified] from bottom of panel.
  4. Sliding/Folding Hardware: Provide manufacturer's standard combination sliding and folding hardware with top, bottom tracks and threshold. All running carriages to be with sealed, self-lubrication, ball bearing multi-rollers. Surface mounted hinges and running carriages will not be allowed. Weight of panels to be borne by the bottom of the track will not be allowed.
    1. Provide upper guide carriage and lower running carriage with four vertical fiber glass reinforced polyamide wheels and two horizontal wheels. The vertical wheels to ride on top of sill track and lie above the water run-off level. Carrying capacity of lower running carriage to be 440 lbs.
    2. Threshold: Provide matching raised sill [OR dark bronze anodized, E6 C34 [OR clear anodized, E6 EV1] flush sill [OR low profile saddle sill].
      SPECIFIER'S NOTE: Note that the flush sill is not Dade County approved.
    3. Hinges: Zinc die cast. Finish: Closest match to finish of frame and panels. Provide stainless steel security hinge pins with set screws.
    4. Adjustment: Provide folding/sliding hardware capable of specified amount of compensation and adjustments without needing to remove panels from tracks, in width, 1/8" (3 mm) per hinge and in height, 3/16" (4 mm) up and down.
  5. Other Components:
    1. Weather stripping: Provide manufacturer's standard double layer EPDM or brush seals with a two layer fiber glass reinforced polyamide fin at both the inner and outer edge of door panels or on frame for sealing between panels and between panel and frame.
    2. Provide tapered pins or machine screws for connecting frame components.

2.03 FABRICATION

  1. Use extruded aluminum frame and panel profiles, corner connectors and hinges, sliding and folding hardware, locking hardware and handles, glass and glazing and weather stripping as specified herein to make a folding glass wall. Factory pre-assemble as is standard for manufacturer and ship with all components and installation instructions.
  2. Sizes and Configurations: See drawings for selected custom dimensions within maximum frame sizes possible as indicated in manufacturer's literature. See drawings for selected number of panels and configuration. Inward [OR outward] opening unit.
    SPECIFIER'S NOTE: Note panel size limit of 3' wide and 8' high for Dade County approval.

2.04 ACCESSORIES

(Edit for project requirements.)

  1. Provide the NanaScreenTM, a series of vertical, collapsible, pleated screen panels. Provide top track, side jambs, and vertical struts in white anodized [OR clear anodized] [OR dark bronze anodized] [OR custom powder coated] aluminum. Provide pleated, polypropylene screen material with patented, floor tracking chain with ¼" (5 mm) floor track. See drawings for selected number of panels and configuration.
  2. Provide matching single or double doors as per drawings.

PART 3 — EXECUTION

3.01 ERECTION

  1. Because of the large dimensions involved and the weight and movement of the panels, verify the structural integrity of the header such that the deflection with the live load is limited to the lesser of L/720 of the span and ¼".
  2. Examine surfaces of openings and verify dimensions; verify rough openings are level, plumb, and square, with no unevenness, bowing, or bumps on floor.
  3. Installation of units constitutes acceptance of existing conditions.

3.02 INSTALLATION

  1. Install frame in accordance with manufacturer's recommendations and installation instructions. Installation has to be in conformance with Miami Dade County, FL Notice of Approval. Properly flash and waterproof around the perimeter of the opening.
  2. Installer to provide appropriate anchorage devices and to securely and rigidly fit frame in place, absolutely level, straight, plumb and square. Install frame in proper elevation, plane and location, and in proper alignment with other work.
  3. If necessary, provide drain connections from lower track.
  4. Install panels, handles and lock set in accordance with manufacturer's recommendations and installation instructions.
  5. If necessary, adjust hardware for proper operation.
  6. Accessories: Screens; install in accordance with screen manufacturer's recommendations and installation instructions.

END OF SECTION

Last updated: 12/24/2007

Brochures

wireframe image

General Brochure (pdf) General [esp] [fr]
Residential Brochure (pdf) Residential
Hospitality Brochure (pdf) Hospitality
Education Brochure (pdf) Education

Learn

wireframe image

Exhilaration
Peace of Mind
Satisfaction
Green Design

Contact NanaWall®

image of phone

Contact us directly, online, or to reach our sales reps.

Template Image